95% SO₂ removal, customized solutions, 60+ years expertise. Xinhuasheng - Get quote now!">
Desulfurization and Denitrification Activated Carbon

Desulfurization and Denitrification Activated Carbon

Product Name: Desulfurization and Denitrification Activated Carbon
Product Description: Specialized activated carbon (often impregnated or modified) designed to capture sulfur oxides and nitrogen oxides.
Character: Black granules or pellets with catalytic properties.
Usage: Flue gas treatment in power plants, industrial exhaust gas purification, and biogas cleaning.
Storage: Store in a cool, dry place. Avoid exposure to open flame.
Package: 25kg drums or bags.
  • Fast Delievery
  • Quality Assurance
  • 24/7 Customer Service

Product Introduction

Desulfurization and Denitrification Activated Carbon – Industrial Flue Gas Treatment Solution 

Our Desulfurization and Denitrification Activated Carbon delivers dual-function emission control in a single system. Designed for mechanical pipe gas situations, this adjusted carbon fabric accomplishes >95% SO₂ evacuation and >80% NOₓ conversion—even at challenging moo temperatures (120-180°C). With pulverize quality ≥90 N and an optimized Φ9mm round and hollow shape, it diminishes fan vitality utilization by 20% whereas supporting up to 3 warm recovery cycles. Supported by 60+ a long time of R&D legacy and defense-grade innovation from Shanxi Xinhuasheng Carbon Fabricating Co., Ltd., you get solid, high-performance treatment that meets the hardest mechanical standards.

Why Choose Our Activated Carbon for Flue Gas Treatment?

Dual-Function Efficiency

You do not require partitioned frameworks any longer. Our fabric handles both sulfur dioxide and nitrogen oxides at the same time. This coordinates approach cuts your add up to hardware speculation by generally 40%. Your operation gets to be less difficult, your impression littler, and your support plan simpler to manage.

Low-Temperature Catalytic Activity

Many industrial processes—steel sintering, glass manufacturing, biomass boilers—operate at lower flue gas temperatures. Traditional catalysts struggle here. Our Desulfurization and Denitrification Activated Carbon uses specially loaded functional groups (carboxyl and hydroxyl) to maintain strong NOₓ conversion even at 120-150°C. You get consistent performance without reheating exhaust gases.

Engineered for Energy Savings

The Φ9mm round and hollow shape isn't self-assertive. This determination equalizations surface range with gas porousness flawlessly. Your framework weight drop remains underneath 1000 Dad, meaning your fans expend 20% less vitality. Over a long time of operation, those investment funds include up significantly.

Built to Last and Regenerate

Industrial operations demand durability. This carbon supports up to three thermal regeneration cycles while keeping more than 90% of its original adsorption capacity. You extend service life, reduce replacement frequency, and lower your long-term operating costs.

Factory Premises & Environment

Technical Specifications

Parameter Value
Iodine Value ≥800 mg/g
Breakthrough Capacity (H₂S) ≥20%
Particle Size 4-6 mm or 8-16 mesh
Crush Strength ≥90 N
Moisture Content ≤5%
SO₂ Removal Efficiency >95%
NOₓ Conversion Rate >80%
Operating Temperature Range 120-180°C
Pressure Drop <1000 Pa
Regeneration Cycles Up to 3 cycles (>90% capacity retention)

Where You Can Apply This Solution

Power Generation Plants

Coal-fired and biomass power stations benefit from integrated desulfurization and denitrification. You simplify compliance with emission standards while reducing capital expenditure.

Steel & Metallurgy

Sintering machines and blast furnace exhaust operate at lower temperatures. Our material excels in these exact conditions, delivering reliable NOₓ and SO₂ control without costly preheating.

Chemical & Petrochemical Industries

Process exhaust often contains complex sulfur and nitrogen compounds. This activated carbon handles mixed contaminants effectively, protecting downstream equipment and the environment.

Biogas & Waste-to-Energy Facilities

H₂S and other sulfur compounds in biogas damage engines and turbines. Our high breakthrough capacity (≥20%) extends equipment life and reduces cleaning frequency.

Application Fields of Activated Carbon

How to Store and Handle

Store your activated carbon in a cool, dry location away from open flames. The material arrives moisture-controlled (≤5%) and ready to use. Standard packaging is 25kg drums or bags, designed for easy handling and moisture protection during transport. Proper storage maintains performance characteristics until installation.

PACKAGING AND TRANSPORTATION

Frequently Asked Questions

Can this supplant isolated SCR and FGD systems?

Yes, completely. It offers coordinates desulfurization and denitrification in one vessel. You dispose of the require for two partitioned frameworks, which ordinarily diminishes your add up to hardware speculation by generally 40%. Establishment is less difficult, and you'll have less components to maintain.

How does it perform in low-temperature steel sintering?

This is where our fabric truly sparkles. It utilizes stacked useful groups—specifically carboxyl and hydroxyl groups—to keep up tall NOₓ change (>80%) indeed at 120-150°C. Conventional SCR catalysts require much higher temperatures, but ours works viably in your existing low-temperature conditions.

What is the advantage of the Φ9mm specification?

This particular distance across optimizes the adjust between surface region and gas porousness. You get greatest contact between pipe gas and dynamic destinations whereas keeping framework weight drop underneath 1000 Dad. The result? Way better treatment proficiency with lower fan vitality costs—a 20% decrease compared to littler particles.

How regularly do I require to supplant the carbon?

That depends on your vent gas composition and stream rates. In any case, our fabric underpins up to three warm recovery cycles whereas keeping up over 90% of unique capacity. Numerous clients discover they can recover or maybe than supplant, altogether amplifying operational life between full changeouts.

Do you offer customization for particular mechanical conditions?

Yes, we do. With 60+ a long time of R&D involvement and collaboration with educate like Tsinghua College and the Chinese Institute of Sciences, we can alter pore structure, surface chemistry, and stacked components to coordinate your correct vent gas parameters. Contact us to talk about your particular requirements.

Our Certificate

Contact Us

Ready to optimize your emission control system? Reach out today: greta@carbonxinhua.com – we'll respond within 24 hours with Desulfurization and Denitrification Activated Carbon solutions.